Vinyl flooring and underfloor heating – a combination that is becoming increasingly popular. Nevertheless, this is an issue that always raises questions. In this article, you can find out which vinyl flooring is suitable for underfloor heating and what you should consider when laying it, so that you can permanently benefit from the benefits of your vinyl flooring on underfloor heating.

A wide range of applications, attractive optics, easy installation, resistant material properties and much more – the advantages of a vinyl floor are obvious.

Underfloor heating also impresses with numerous advantages such as cost-effectiveness, cleanliness and environmental friendliness.

In the case of single- and multi-family houses, the proportion of underfloor heating systems as a heating system is now almost 50 percent.

It is therefore not surprising that the installation of vinyl flooring on underfloor heating is also becoming increasingly popular.

This is what matters:

Criteria for vinyl flooring on underfloor heating

While there was a lot of discussion about the suitability of vinyl flooring on underfloor heating in the past, the combination has now proven itself through predominantly positive experiences.

In principle, there is absolutely no objection to the installation of vinyl flooring on underfloor heating, provided that certain conditions are taken into account in advance:

Exact Temperature

The most decisive criterion for laying vinyl flooring on underfloor heating is whether the chosen heating system ensures reliable temperature control.

In contrast to other floor coverings, such as laminate, parquet or tiles, a vinyl floor primarily reacts to heat.

If the temperature rises, the material expands strongly, the heat decreases, it tightens again.

Strong temperature fluctuations or too fast temperature rises can lead to unsightly joint formation or permanent damage to the vinyl floor.

Therefore, it is important that the underfloor heating does not heat the vinyl floor too much or too quickly.

The maximum surface temperature of the vinyl floor heating should not exceed 27° C.

Hot water underfloor heating vs. electric underfloor heating

The classic version of hot water underfloor heating generates heat by flowing warm water through plastic or copper pipes.

What is often seen as a disadvantage has a positive effect for vinyl floors:

The sluggish lead time of a hot water underfloor heating ensures a slow heating of the vinyl floor and thus protects the material.

In addition, the temperature in the pipes remains relatively constant between 26 and 28° C throughout the heating period.

The flow temperature – i.e. the temperature at which the water circulates through the pipes – has no influence on the vinyl floor and can therefore be quite higher.

Especially with modern low-temperature underfloor heating systems, the surface temperature can be precisely regulated by built-in thermostats.

It should be noted, however, that the installation of a hot water underfloor heating system involves relatively high effort and a certain height must be maintained for the final floor ingesis. Especially in the case of renovation work on existing buildings, the building conditions must therefore be carefully checked in advance.

Otherwise, however, hot water underfloor heating must be used without hesitation for vinyl floors.

On the other hand, caution should be exercised in the case of electric underfloor heating systems.

In this variant, the heat is generated by the combination of current and voltage, which leads to a significantly faster and sometimes higher temperature increase than with hot water underfloor heating.

Modern models also have the necessary technical requirements for temperature control, but the laying of vinyl floors on electric underfloor heating is not recommended.

Expert Heating installation

In general, the installation of the underfloor heating under a vinyl floor should be carried out exclusively by a specialist.

This ensures that the substrate is prepared professionally and that existing moisture in the screed has been sufficiently heated before the vinyl floor is laid.

In addition, not only must the construction height on the entire floor area be precise, but also the pipes of the underfloor heating must be installed in such a way that a uniform distribution of heat on the vinyl floor is guaranteed. Even spot heat nests can cause damage to the vinyl floor.

Special Footfall sound insulation

In order to ensure that the heat from the underfloor heating is ultimately transferred energy-efficiently to the surface of the vinyl floor, a maximum heat transmission resistance of 0.15 m2K/W is required.

In addition to the thickness of the floor and the thermal conductivity of the material, the footfall sound insulation or steam brake used also affects this value.

There are special footfall sound insulation systems for underfloor heating, on which a vinyl floor is to be laid.

The quartz sand most contained in it stores heat and releases it to the room.

Other insulating materials such as styrofoam, cork or foam, on the other hand, preventthe heat from spreading and are therefore unsuitablefor use on vinyl floors on underfloor heating.

Contrary to its previous reputation, vinyl floors achieve excellent results in terms of energy efficiency and heat performance.

Due to the low heat transfer resistance and the good thermal conductivity, rooms with vinyl flooring can be effectively heated by underfloor heating.

Which vinyl floor is designed for installation on Underfloor heating suitable?

If an adequate underfloor heating system has been found and the necessary preparations have been made, the crucial question arises as to the right vinyl flooring.

All vinyl floors suitable for installation on underfloor heating systems are specially marked.

If a vinyl floor does not have a corresponding marking, it is essential to receive a written confirmation of the suitability for underfloor heating from the vinyl floor manufacturer before laying it.

The extent to which a vinyl floor is suitable for use on underfloor heating also depends on the design and the type of installation.

Basically, a distinction is made between vinyl on HDF carrier plates and solid or full vinyl.

Vinyl on HDF is similar to laminate and is floating using a click system. There are also click systems that are made entirely of vinyl.

The thinner full vinyl, on the other hand, consists of homogeneous planks and is only glued to the screed on a full surface.

Types of laying from vinyl flooring to underfloor heating

Basically, all types of laying work to install a vinyl floor on hot water underfloor heating systems.

However, there are differences in energy efficiency, albeit mostly minor.

Solid or full vinyl flooring, which is glued to the surface, is best suited for installation on underfloor heating.

The direct connection between the vinyl floor and the substrate due to suitable adhesives as well as the relatively low material thickness of a maximum of 5 – 6 mm ensure optimum thermal conductivity.

But also the floating laying of vinyl floors on underfloor heating is possible.

However, in this type of laying, in contrast to the fully bonded installation, a thin air layer forms between the substrate and the vinyl floor, which impairs the thermal conductivity.

In addition, in the case of floating vinyl floors on underfloor heating, a footfall sound insulation is necessary, which additionally affects the heat transmission resistance.

In particular, vinyl floors on HDF carriers, which are usually much thicker than full vinyl floors, are less suitablefor laying on underfloor heating.

In addition to the footfall sound insulation,which is already integrated in many vinyl planks, an additional steam brake is also required for mineral substrates (e.g. cement screed or anhydrite screed) so that rising moisture cannot damage the carrier material of the vinyl floor.

In any case, when laying vinyl flooring on underfloor heating, it is essential to observe the manufacturer’s instructions and installation instructions.

Laying vinyl floor on tiles with underfloor heating

Often a vinyl floor is also laid on existing tiles,under which there is already underfloor heating.

In this case, too, the following applies:

Even if it is basically possible to lay a floating (click) vinyl floor, it is recommended to use a fully glued full vinyl floor to prevent heat loss.

Is a vinyl floor on underfloor heating Harmful?

A question that until a few years ago was quite justified:

Vinyl floors used to contain harmful plasticizersthat developed toxic vapours during heating, for example through underfloor heating.

Today, however, vinyl floors in Europe are subject to strict conditions, which ensure that the use of harmful phthalates is dispensed with.

Therefore, unless an old vinyl floor is used, the laying of vinyl flooring on underfloor heating has no negative health effects.